Solenoid Pumps Products   Structurer & Mechanism   Applications   Selection Factors    Option Board

Structurer & Mechanism

This is solenoid driven plunger/piston pump, which features: compact structure, high pressure output, no leakage, mini size, ideal dynamic regulation, small flow rate, etc

Current wave for solenoid pump is usually DC half wave.

(Picture A) When the solenoid / coil is energized, plunger moves rightwards under magnectic attracting force. Consequentially, the Pressure Chamber gets bigger and its pressure lower (P<Pin ), so liquid flows from inlet to Pressure Chamber.
(Picture B) When the solenoid is deenergized, the plunger moves leftwards with pressing of spring. Consequentially, the Pressure Chamber gets smaller and its pressure higher (P>Pout ), so liquid flows from Pressure Chamber to outlet.

Power supply is uaually 50Hz or 60 Hz after filtering. Plunger motion frequency is also same frequency. Liquid is pumped continuously.